3V0-23.25 Exam Question 6

A customer attaches an external Fibre Channel (FC) VMFS datastore to a VMware Cloud Foundation (VCF) workload domain for backup staging. The administrator must confirm that the datastore is visible to all hosts, and that path and device health alarms will trigger should a fabric link or path fail.
Which action should the administrator take to verify this?
  • 3V0-23.25 Exam Question 7

    An architect is designing a vSAN Original Storage Architecture (OSA) cluster for a VMware Cloud Foundation (VCF) Management Domain. The following details were made available:
    * 12 hosts, each host with: 3 x 800 GB NVMe (cache) and 12 x 3.84 TB SAS SSD (capacity).
    * Planned configuration: 3 disk groups per host (1 NVMe + 4 SSD each).
    * Storage policy: FTT = 2 (RAID-1), Checksum. Deduplication and Compression are Enabled.
    * Network: 25 GbE dedicated vSAN network fabric, properly configured for jumbo frames.
    After deployment and loading test data to 70% capacity, the operations team reported extended resync times when two hosts are placed into maintenance mode with "Ensure Accessibility" selected and no hardware or network bottlenecks were detected.
    How can the administrator explain the observed behavior?
  • 3V0-23.25 Exam Question 8

    A storage architect is designing a vSAN solution that enforces quotas and Access Based Enumeration (ABE) on all file shares.
    What should the architect highlight as a design decision implication?
  • 3V0-23.25 Exam Question 9

    A clustered legacy application is scheduled for decommissioning at the end of the month. While in use, it stored application and quorum data on a pair of vSAN iSCSI Target LUNs.
    After the vSAN iSCSI Target Service is disabled, what will happen to the existing targets and LUNs?
  • 3V0-23.25 Exam Question 10

    An administrator has been tasked with recommending a principal storage type for a new cluster within an existing VMware Cloud Foundation (VCF) Workload Domain.
    The following information has been provided:
    * The customer has a 25GbE capable network.
    * The customer has an existing 3rd party storage solution that supports connectivity by either FibreChannel and NFS
    * The new cluster will consist of two host servers that will be recycled from a previous project.
    * Each of the host servers have the following configuration:
    o One 500GB Enterprise-grade SSD drive.
    o Two 2-Port IOGbE network cards.
    * There is no budget for additional hardware.
    Which approach should the administrator recommend for the principal storage type?