3V0-23.25 Exam Question 31
An architect has been tasked with designing a vSAN OSA storage solution for a VMware Cloud Foundation (VCF) Private Cloud. The following requirements and constraints have been gathered from the client:
* 2 x 4 TB NVMe disks per host
* 6 hosts
* FTT=1/RAID-5 for all deployed Virtual Machines
* Expected Dedupe/Compression Ratio = 2 (100%)
* Reserve enough capacity to rebuild a host completely in case of a failure (Host Rebuild Reservation)
* Operational Reserve of 10%
* Expected Overhead for Filesystem, Object, etc. of 25%
What is the approximate expected usable capacity of the resulting array?
* 2 x 4 TB NVMe disks per host
* 6 hosts
* FTT=1/RAID-5 for all deployed Virtual Machines
* Expected Dedupe/Compression Ratio = 2 (100%)
* Reserve enough capacity to rebuild a host completely in case of a failure (Host Rebuild Reservation)
* Operational Reserve of 10%
* Expected Overhead for Filesystem, Object, etc. of 25%
What is the approximate expected usable capacity of the resulting array?
3V0-23.25 Exam Question 32
What is a vSAN disk group composed of?
3V0-23.25 Exam Question 33
An administrator is planning the deployment of a new VMware Cloud Foundation (VCF) Workload Domain.
The storage design decisions for the solution are:
* NFS
* NVMe over RDMA
* No local storage is available to the hosts
What is the storage solution build order for the Workload Domain?
The storage design decisions for the solution are:
* NFS
* NVMe over RDMA
* No local storage is available to the hosts
What is the storage solution build order for the Workload Domain?
3V0-23.25 Exam Question 34
Which vSAN feature ensures data availability across sites?
3V0-23.25 Exam Question 35
A Network Administrator is troubleshooting an HCI Mesh configuration between Cluster-A (Server) and Cluster-B (Client). The administrator attempts to mount Cluster-A's vSAN datastore onto Cluster-B, but the operation fails.
The administrator checks the Skyline Health dashboard on vCenter:
```
[Skyline Health > vSAN > HCI Mesh]
Check: Remote Datastore Connectivity
Status: Failed
Source: Cluster-B (Client)
Target: vsanDatastore-Cluster-A
Details: 2 of 16 hosts failed ping
Check: MTU Uniformity
Status: Warning (Mismatch detected)
```
Based on the health output and HCI Mesh requirements, which TWO actions will resolve this mounting failure? (Choose 2.)
The administrator checks the Skyline Health dashboard on vCenter:
```
[Skyline Health > vSAN > HCI Mesh]
Check: Remote Datastore Connectivity
Status: Failed
Source: Cluster-B (Client)
Target: vsanDatastore-Cluster-A
Details: 2 of 16 hosts failed ping
Check: MTU Uniformity
Status: Warning (Mismatch detected)
```
Based on the health output and HCI Mesh requirements, which TWO actions will resolve this mounting failure? (Choose 2.)