5V0-21.21 Exam Question 26
An administrator is planning to deploy workloads on a six node vSAN cluster, and all nodes are distributed equally across three racks.
Which action is required to ensure that the workload VMs remain compliant with the default vSAN policy after a complete rack failure?
Which action is required to ensure that the workload VMs remain compliant with the default vSAN policy after a complete rack failure?
5V0-21.21 Exam Question 27
A 4-node vSAN cluster is configured with an erasure coding storage policy. The Ensure Accessibility maintenance mode was selected. While performing the maintenance, a second node fails.
What will be the impact on the vSAN cluster?
What will be the impact on the vSAN cluster?
5V0-21.21 Exam Question 28
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1.
During the discovery phase, the consultant found the following information about the existing environment:
* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.
* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.
* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.
* The vSAN Cluster has the following configuration:
- vSAN version: 6.6.1
- Number of vSAN nodes: 10
- Encryption: enabled
- Deduplication and Compression: enabled
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- VMware vSphere ESXi version: 6.5 Update 3
- CPU: 2 processors, 20 cores
- RAM: 768GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)
During the discovery phase, the consultant found the following information about the existing environment:
* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.
* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.
* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.
* The vSAN Cluster has the following configuration:
- vSAN version: 6.6.1
- Number of vSAN nodes: 10
- Encryption: enabled
- Deduplication and Compression: enabled
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- VMware vSphere ESXi version: 6.5 Update 3
- CPU: 2 processors, 20 cores
- RAM: 768GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)